JIAXING MES NEW ENERGY TECHNOLOGY CO., LTD
Products
Contact Us
  • Contact Person : Mr. Alan Lin
  • Company Name : JIAXING MES NEW ENERGY TECHNOLOGY CO., LTD
  • Tel : 86-573-86579525
  • Fax : 86-573-86579525
  • Address : ZHEJIANG,JIAXING,West of dayang bridge, north of Huhang road,  fouth group of Dongfang villiage, Ganpu town, Haiyan county, Jiaxing city,  Zhejiang province
  • Country/Region : China
  • Zip : 314302

Commercial Air Source Heat Pumps For Lowest Ambient Temperature -15℃ Area

Commercial Air Source Heat Pumps For Lowest Ambient Temperature -15℃ Area
Product Detailed
Related Categories:Agricultural Product Stock
Commercial air source heat pumps for waraming forlowest ambient temperature -15℃ area This is air source heat pumps for commercial building warming, it is the normal one which can work in lowest ambient temperature -15℃, the highest capacity can reach 145KW and the control system has RS485 function so that more heat pumps can work together.We have great experience for all kinds of heat pumps, with the professional equipment, sales, engineers and workers, we will supply the best products for you.Product Info.CompressorCopeland scroll or Panasonic scrollCapacity9KW,15KW,20KW,30KW,40KW,55KW,60KW,72KW, 90KW, 108KW,145KWRefrigerantR410ACondenser"ND" Shell & Coil heat exchangerEvaporatorFinned tube heat exchanger(high quality, with stainless steel 304 of frame)AC contactor & RelaySchneiderElectronic expansion valveJapan Saginomiya or World No.1 SanhuaReversing valveWorld No.1 SanhuaControllerLCDPackageWooden case or CartonFastenersStainless steel 304Additional Info. Delivery time25 days after order confirmedWarranty time24 months after shipmentPayment termT/T or L/C at sightProduction capacity400 units per monthBrandMES or OEM    Parameters Warmer-CV series(Commercial Air source heat pump for House heating & Hot water)WM-CV-1609WM9s-CV5WM15s-CV5WM9-CV5WM15-CV5WM20-CV5WM30-CV10WM40-CV10WM55-CV10WM60-CV20WM72-CV20WM90-CV20WM108-CV20WM145-CV40Rated house heating capacitykW91591520304055607290108145Rated input power for house heatingkW2.744.572.84.576.279.0612.1216.6218.422.0927.6133.1344.48Rated input current for house heatingA12.220.335.38.6411.8517.1322.9131.434.7941.7452.1862.6184.06Heating performance coefficient (COP)/3.283.283.213.283.193.313.33.313.263.263.263.263.26Hot water heating capacitykW12191219253550657585105125165Input power for hot water heatingkW2.724.292.714.285.647.9211.3614.7316.8919.1923.728.2837.33Input current for hot water heatingA11.8818.734.947.7910.2714.4120.6827.8330.7434.9243.1451.4767.94Hot water performance coefficient(COP)/4.414.434.424.444.434.424.44.414.444.434.434.424.42Maximum input powerkW3.545.583.535.567.3410.2914.7718.8521.9624.9430.8136.7648.53Maximum input currentA15.4524.356.6710.5113.8719.4627.9235.841.547.1458.2469.4991.72Power supply1N 220V/50Hz3N 380V/50Hz(Special power supply for option)(Special power supply for option)CompressorTypeHermetic scroll typeStart modeDirectly start(Soft start for option)QuantitySet1111122222334Water SideHeat exchangerShell & coil(tube) heat exchangerWater flowm3/h2.13.32.13.34.368.611.212.914.618.121.528.4Water pressure dropkPa≤45≤53≤45≤53≤55<60<60<60<65<68<70<70<75Connection sizeDNDN25DN25DN25DN25DN25DN32DN32DN50DN50DN50DN50DN65DN80Air SideExchangerFinned tube heat exchangerRated Air flowm3/h350063203500632075001250014800148002600026000390003900052000Rated output power of fan motorW12025012025037055075075011001100150015002200Protections1. High pressure and low pressure protection,2. Anti-freezing protection,3. High temperature protection,4. Too big of the water temperature difference for outlet and inlet protection,5. Overload protection,6. Lack phase protection,7. Reverse phase protection, etc..RefrigerantThrottle typeElectronic expansion valveTypeR410aQuantitykg1.92.81.92.84.12.8×24.1×25.2×23.2×47.6×26.2×37.6×37.6×4NoiseDB(A)≤55≤63≤55≤63≤65≤65≤66≤68≤70≤72≤73≤75≤78Dimensionmm710x710x1100990x990x18001000x2050x18502000x2050x1850Wooden case package dimensions(L*W*H)mm766x766x11461046x1046x19681056x2106x20182056x2106x2018Net weightkg1081351081351653404004856056608358401230Gross weightkg12315012315018037043051564069587087512651. Heating standard condition: Dry-bulb temperature 7℃, wet bulb temperature 6℃;  Cold water inlet temperature 40℃, Hot water outlet temperature 45℃;2. Hot water standard condition: Initial water temperature 15 ℃, the setting  water temperature 55 ℃; Dry-bulb temperature 20℃, wet bulb temperature 15℃.The above parameters based on Refrigearnt R410A, for parameters based on other refrigerants please contact us.The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.


Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.